Repository logo
Communities & Collections
All of DSpace
  • English
  • العربية
  • বাংলা
  • Català
  • Čeština
  • Deutsch
  • Ελληνικά
  • Español
  • Suomi
  • Français
  • Gàidhlig
  • हिंदी
  • Magyar
  • Italiano
  • Қазақ
  • Latviešu
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Српски
  • Svenska
  • Türkçe
  • Yкраї́нська
  • Tiếng Việt
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "López Sánchez, Byron Leonardo"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • No Thumbnail Available
    Item
    Las aguas residuales y su influencia en la calidad de vida de los pobladores del barrio central de la parroquia Pacayacu, cantón Lago Agrio, provincia de Sucumbíos
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Carrera de Ingeniería Civil, 2014) López Sánchez, Byron Leonardo
    El presente trabajo es una contribución al mejoramiento de la calidad de vida de los habitantes del barrio Central, por medio del diseño de un sistema de alcantarillado sanitario, el cual se complementa con Humedales Artificiales. La función de dicho sistema será transportar las aguas residuales de las viviendas por medio de la fuerza gravitacional a través de tubería PVC, que adicionalmente cuenta con obras accesorias como pozos de visita y registros domiciliares para finalizar con el tratamiento del agua y poder desalojarla sin causar impactos en el medio ambiente. Para el desarrollo del mismo, se necesitan tomar en cuenta factores como: el crecimiento poblacional y el estudio topográfico. En el diseño propiamente dicho, se considera: el área que se va a servir, período de diseño, caudales de infiltración, conexiones ilícitas; todo basado en las normas para el diseño de redes de alcantarillado, como las normas INEN y las normas de la Subsecretaría de Saneamiento Ambiental ex IEOS. Con el diseño completamente terminado, se elabora un juego de planos, se calculan los materiales y mano de obra necesarios para la ejecución del proyecto. Al término de este proceso, se entrega el estudio y diseño completo del sistema de alcantarillado a la Municipalidad de Lago Agrio, para que en el futuro pueda realizar el proyecto de la mejor manera y contribuir con el desarrollo del barrio Central.
  • No Thumbnail Available
    Item
    Análisis estático no lineal (Push Over) de los talleres de la Facultad de Ingeniería Civil y Mecánica y de la Facultad de Ingeniería en Sistemas Electrónica e Industrial, con aisladores sísmicos, ubicadas en el campus Huachi de la Universidad Técnica de Ambato
    (Universidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica. Maestría en Ingeniería Civil con Mención en Estructuras Metálicas, 2022) López Sánchez, Byron Leonardo; Ureña Aguirre, Maritza Elizabeth
    This research work presents a comparative analysis of the structural behavior of a conventional structure and another with the implementation of seismic isolators, which are devices that allow the building to deform elastically and dissipate energy during the occurrence of earthquakes of considerable magnitude. The structures analyzed were the workshops of the faculties of: Civil and Mechanical Engineering and Systems, Electronics and Industrial Engineering and they are classified as special according to the Ecuadorian Construction Standard (NEC 2015), and present a structural system of special earthquake resistant gantries made of hot rolled steel with stiffening diagonals, they are also used as laboratories for the production area and as a higher education center.xxiii As a first study, a linear analysis of the structures was performed to verify their current state by analyzing their vibration period, displacements and permissible drifts, then a non-linear static analysis was performed to determine their seismic performance, and then the isolation system was pre-dimensioned. It was designed taking as a priority the ASCE/SEI 7-10 standard, the dead loads of the building plus 30 percent of the live load above the isolation system and based on the information provided by the manufacturer. It should be taken into account that there are a large number of options of anti-seismic devices to improve the performance and behavior of a structure; in this case study, the lead core elastomeric isolator (LRB) was chosen. Subsequently, all the established limits such as drifts, shear and displacements were verified, taking into account the provisions of the Ecuadorian Construction Standard. For the workshop of the Faculty of Civil and Mechanical Engineering with isolated base, the floor drifts were reduced by 64 percent compared to the structure without isolation, for the basal shear and horizontal displacements a reduction of 73 and 51 percent respectively, likewise for the workshop of the Faculty of Systems, Electronics and Industrial Engineering the floor drifts, shear and displacement were reduced by 69, 74 and 63 percent respectively.

DSpace software copyright © 2002-2025 LYRASIS

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify