Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uta.edu.ec/jspui/handle/123456789/35596
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorRamírez Cabrera, Wladimir José-
dc.contributor.authorMartínez Montoya, Christopher Diego-
dc.date.accessioned2022-08-08T23:33:28Z-
dc.date.available2022-08-08T23:33:28Z-
dc.date.issued2022-07-
dc.identifier.urihttps://repositorio.uta.edu.ec/jspui/handle/123456789/35596-
dc.descriptionEn el presente trabajo de titulación se realizó el análisis y diseño estructural de un edificio de hormigón armado. Mediante este modelo se realizó un análisis estructural convencional usando un espectro de diseño con un R=8 tomando en cuenta los fundamentos especificados por las normas NEC-SE-DS y ACI318. Posteriormente se realizó el análisis de la misma edificación con la incorporación de amortiguadores viscosos utilizando los fundamentos especificados por la norma ASCE 7-16, obteniendo coeficientes de amortiguación para los disipadores utilizados en la estructura y derivas menores al 0.5 por ciento. Se realizó un análisis económico comparando el costo de reforzamiento para la estructura convencional, esperando un daño considerable a largo plazo en caso de un sismo severo, y el diseño de la estructura con la incorporación de amortiguadores viscosos, esperando derivas de hasta máximo 0.5 por ciento y un desempeño de ocupación inmediata en caso de un sismo de raro. Al final del trabajo se concluye que la incorporación de amortiguadores viscosos brinda gran aporte en la disipación de energía sísmica disminuyendo la disipación no lineal por parte de la estructura y por ende reduciendo el daño estructural en la edificación.es_ES
dc.description.abstractIn this degree work, the structural analysis and design of a reinforced concrete building was carried out. By means of this model, a conventional structural analysis was performed using a design spectrum with an R=8 taking into account the fundamentals specified by the NEC-SE-DS and ACI318 standards. Subsequently, the analysis of the same building was carried out with the incorporation of viscous dampers using the fundamentals specified by ASCE 7-16, obtaining damping coefficients for the dissipaters used in the structure and drifts of less than 0.5 percent. An economic analysis was carried out comparing the cost of reinforcement for the conventional structure, expecting considerable long-term damage in the event of a severe earthquake, and the design of the structure with the incorporation of viscous dampers, expecting drifts of up to 0.5 percent and immediate occupancy performance in the event of a rare earthquake. At the end of the work it is concluded that the incorporation of viscous dampers provides a great contribution in the dissipation of seismic energy by decreasing the nonlinear dissipation by the structure and therefore reducing the structural damage in the building.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Técnica de Ambato. Facultad de Ingeniería Civil y Mecánica, Carrera de Ingeniería Civiles_ES
dc.rightsopenAccesses_ES
dc.subjectAMORTIGUAMIENTO VISCOSOes_ES
dc.subjectDERIVA DE PISOes_ES
dc.subjectDISIPACIÓN SÍSMICAes_ES
dc.subjectHORMIGÓN ARMADOes_ES
dc.subjectDISEÑO ESTRUCTURALes_ES
dc.titleDiseño estructural de un edificio de hormigón armado con amortiguadores viscososes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones: Ingeniería Civil

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tesis I.C. 1589 - Martínez Montoya Christopher Diego.pdfTESIS A TEXTO COMPLETO6,5 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.